Whether the unit you need is for feeding mechanisation or the treatment of various substrates, KUHN FEEDING PROCESS solutions will meet your specific requirements and expectations.
Find your nearest dealer Download Brochure
CENTRAMIX 9.1 DL | CENTRAMIX 10.1 DL | CENTRAMIX 11.1 DL | CENTRAMIX 12.1 DL | CENTRAMIX 13.1 DL | CENTRAMIX 14.1 DL | CENTRAMIX 15.1 DL | CENTRAMIX 17.1 DL | CENTRAMIX 20.1 DL | CENTRAMIX 4.1 DS | CENTRAMIX 6.1 DS | CENTRAMIX 8.1 DS | CENTRAMIX 10.1 DS | CENTRAMIX 12.1 DS | CENTRAMIX 18.2 DL | CENTRAMIX 22.2 DL | CENTRAMIX 25.2 DL | CENTRAMIX 27.2 DL | CENTRAMIX 30.2 DL | CENTRAMIX 16.2 DS | CENTRAMIX 20.2 DS | CENTRAMIX 22.2 DS | |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
Capacity (m3) | 9 | 10 | 11 | 12 | 13 | 14 | 15 | 17 | 20 | 4 | 6 | 8 | 10 | 12 | 18 | 22 | 25 | 27 | 30 | 16 | 20 | 22 |
Mixing system | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 1 vertical auger | 2 vertical augers | 2 vertical augers | 2 vertical augers | 2 vertical augers | 2 vertical augers | 2 vertical augers | 2 vertical augers | 2 vertical augers |
Overall height (m) | 2.26 | 2.38 | 2.49 | 2.62 | 2.74 | 2.87 | 3 | 3.24 | 3.44 | 2.10 | 2.35 | 2.43 | 2.76 | 3.01 | 2.29 | 2.61 | 2.88 | 3.01 | 3.15 | 2.36 | 2.71 | 2.96 |
Overall width (m) | 2.83 | 2.83 | 2.83 | 2.84 | 2.85 | 2.86 | 2.88 | 2.90 | 2.92 | 2.27 | 2.29 | 2.36 | 2.36 | 2.36 | 2.52 | 2.52 | 2.52 | 2.52 | 2.52 | 2.36 | 2.36 | 2.36 |
Overall length (m) | 4.25 | 4.25 | 4.25 | 4.27 | 4.30 | 4.33 | 4.36 | 4.42 | 4.47 | 3.68 | 3.82 | 4.25 | 4.29 | 4.36 | 6.86 | 6.86 | 6.86 | 6.86 | 6.96 | 6.61 | 6.64 | 6.71 |
Unladen weight (kg) | 3,514 | 3,590 | 3,619 | 3,672 | 3,715 | 3,796 | 3,855 | 3,957 | 4,051 | 1,734 | 2,016 | 2,694 | 2,764 | 2,884 | 6,060 | 6,190 | 6,340 | 6,450 | 6,385 | 5,100 | 5,215 | 5,350 |
Maximum payload of the motor (t) | 7.7 | 7.7 | 7.7 | 7.7 | 7.7 | 9.5 | 9.5 | 9.5 | 9.5 | 2.8 | 4.7 | 7.7 | 7.7 | 7.7 | 9.5 | 9.5 | 9.5 | 11.5 | 11.5 | 9.5 | 9.5 | 9.5 |
Power supply required | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet | 3 phases 400v + one earth availiable under the electric cabinet |